Skip to main content
Search

# U-Net

27 related articles

Subscribe to updates
  1. bioRxiv

    Cryo-FIB-SEM volumes stop drowning in charging artifacts: a two-stage restoration lets a standard FIB-SEM membrane predictor read them directly

    Cryo focused-ion-beam scanning electron microscopy images cells in a near-native hydrated state in 3D, but charging artifacts, noise and weak membrane contrast have long hampered interpretation. A post-acquisition two-stage deep-learning pipeline translates cryo images toward the conventional room-temperature FIB-SEM domain: stage one suppresses large-scale artifacts slice by slice, and stage two uses five consecutive slices to enhance membrane contrast. On 164 held-out synthetic images, stage one raised mean paired PSNR by 16.74 dB over degraded inputs; across four experimental datasets, visible artifacts decreased and membranes became clearer, and the pretrained CebraNET membrane predictor could be applied directly to the processed volumes without retraining.

  2. arXiv

    ChlCast forecasts chlorophyll-a at about 4 km: against the Copernicus operational system, errors fall by up to 70% on satellite reference fields

    ChlCast is an observation-driven deep learning model that issues daily surface chlorophyll-a forecasts out to 10 days at roughly 4-km resolution between 60°S and 60°N. The operational Copernicus global ocean biogeochemical forecasting system previously ran on a 0.25° grid, where fine-scale structure is weakened by coarse-grid averaging. Against satellite Level-4 chlorophyll-a fields, ChlCast lowers mean absolute error and root mean square error by 70.74% and 47.63%; against independent BGC-Argo in situ observations, the two errors fall by 35.03% and 13.07%.

  3. arXiv

    Cloud tomography drops from half an hour to 3.5 seconds: HybridCT also cuts extinction error on synthetic shallow clouds

    Large-scale observations of the three-dimensional interior of low clouds have been missing because physics-based tomography repeats expensive 3D radiative-transfer calculations, a cost that has kept it from large, realistic cloud scenes. HybridCT splits the problem: a U-Net estimates cloud optical thickness projections from multi-angle passive radiances, and SART then explicitly inverts those projections into a 3D extinction field. On a synthetic low-cloud scene it reconstructs extinction with RMSE 13.3 km⁻¹ in 3.5 s, against 22.7 km⁻¹ in about 30 min for the physics baseline AT3D.

  4. arXiv

    JAX-WAVE turns inverse wave design into one forward pass: 45% lower error than FISTA inside 5 ms

    In a heterogeneous medium, making a wave field take a prescribed shape at a set time means working backward to an initial pressure distribution, and previously every target and every medium required a fresh numerical inversion. JAX-WAVE trains a shared neural network to map the desired terminal field and a known wave-speed map directly to a bounded initial pressure, with training signal supplied by a differentiable finite-difference time-domain solver and no pre-optimized control labels. On an independent confirmation set, three trained models reach 25.24% error on unseen geometric targets and 4.77% on unseen reachable targets; within a 5 ms median online budget the learned map cuts mean error by 45% relative to accelerated numerical inversion on the heterogeneous benchmark.

  5. bioRxiv

    CryoEM maps no longer just show a shape: cryoID2 pairs sequence and structure to pick PfA-M17 out of 166 proteins

    CryoEM can reconstruct a density map yet often cannot say which molecule the map contains, and matching hundreds or thousands of mass-spectrometry or genome-derived candidates by hand is a bottleneck. CryoID2 uses three 3D U-Nets to predict structure classes, key-atom positions and reduced residue or nucleotide types from the map, turns them into short sequence queries that rank candidates, then rigidly fits the candidates' PDB or AlphaFold models back into the density and ranks them by agreement. In a 166-protein mass-spectrometry pool it placed PF3D7_1446200/PfA-M17 first and selected PDB 4ZX8 as the best structural model; on the RNA side it ranked the Ca-raiA-containing interval fourth in a genome-derived non-coding pool, and structural evaluation then put PDB 9E73 first.

  6. Ammonia inversions no longer need 60 chemistry runs: EnsAI builds the ensemble 3300 times faster

    Ammonia emissions inversions rely on ensembles to carry meteorology-dependent error covariances, but each ensemble means repeatedly running the GEM-MACH chemistry model. EnsAI replaces that with a U-Net that maps ammonia emissions perturbations plus temperature and wind fields directly to surface concentration perturbations, producing a week of simulated data per member in 7 seconds against roughly 6.5 hours for GEM-MACH on 720 nodes. Inversions using the EnsAI ensemble gave annual total emissions 2.6% lower than the GEM-MACH ensemble inversions, with monthly totals within 10% for every month.

  7. Saliency maps for medical image classifiers stop guessing from gradients: unsupervised training lets a frozen classifier check the mask

    Saliency maps for convolutional classifiers on medical images now have a new training route: SalientNet needs no annotated saliency ground truth and instead requires the generated mask to keep enough information for a frozen classifier to reproduce its original prediction within a controlled tolerance. Across BreakHis, Brain MRI ND5 and FracAtlas, it reaches higher faithfulness (Win %) and lower prediction Drop (%) than Grad-CAM, Grad-CAM++ and LIME in nearly all dataset-architecture combinations, and on FracAtlas its maps correlate spatially with practitioner-annotated fracture regions, with a mean ground-truth active fraction of up to 0.96 for ResNet-18.

  8. Sleep staging stops picking electrodes: any EEG-EOG mix scores a night, and resolution drops to seconds

    Sleep staging has long depended on fixed electrode sets and 30-second expert-scored epochs, which makes multi-center studies hard to harmonize. AnySleep fuses any number of EEG and EOG channels through channel attention, trained and validated on 20,589 overnight recordings from 28 datasets, matching or slightly exceeding U-Sleep at 30-second epochs and staying strong with no EOG or a single derivation. At sub-30-second resolution, the share of expert-annotated arousal time overlapping predicted Wake rises from 7.7% at 30 seconds to 57.7% near 2 seconds.

  9. X-ray super-resolution stops borrowing a natural-image eye: swapping VGG perceptual loss lifts ESRGAN from 22.21 to 34.04 dB PSNR

    Medical X-ray super-resolution has long relied on VGG perceptual loss designed for natural images, and reconstructed structure can drift from anatomy. A domain-aware loss called USELoss replaces VGG features with multi-scale features from a lightweight U-Net encoder and adds a Sobel edge constraint, applied with identical loss weights to both ESRGAN and HAT. On the PadChest chest X-ray test set, ESRGAN rises from 22.21 to 34.04 dB PSNR and from 0.5545 to 0.9160 SSIM, with edge error cut by about 46%.

  10. Electron tomography fills its missing wedge: self-supervised network cuts 3D atomic localization error from 21 to 14 picometers

    Limited-angle atomic electron tomography leaves a missing wedge because specimens cannot be tilted far enough, degrading depth resolution and atomic localization. RESIRE-Net uses only the input dataset: it rotates the reconstructed volume, projects it at the experimental tilt angles, reconstructs each synthetic tilt series with RESIRE, and trains a 3D U-Net on the resulting pairs to approximate the inverse of the missing-wedge operator. On multislice-simulated metallic-glass and medium-entropy-alloy nanoparticles, 3D positional RMSD falls from 21 to 14 picometers and from 24 to 15 picometers, with atom recovery and elemental classification improving as well.