Skip to main content
Search

# Data Augmentation

9 related articles

Subscribe to updates
  1. arXiv

    A frozen tabular foundation model as candidate generator: propeller-compatible stern designs rise from 1.4% to 99.3%

    Engineering design often has only 10 to 1,000 evaluated designs because simulations and experiments are costly. GenPFN trains no new generator: a frozen TabPFN classifier reads labeled designs, candidates are interpolated between desired designs and updated with classifier gradients and Gaussian noise, and every candidate is evaluated by the problem's own constraints and objectives. Across fourteen engineering problems, GenPFN v1 has higher class satisfaction and lower realism distance than the tested CTGAN, TVAE and TabDDPM; in the stern case, 993 of 1,000 candidates passed geometric checks and met the propeller-placement area requirement, versus 28 of 2,000 random context designs.

  2. Otoendoscopic images stop relying on text alone: CLNA turns unwritten visual variation into an adjustable latent, cutting FID from 52.91 to 10.11

    Otoendoscopic image synthesis has been limited because text prompts state a diagnosis but not visual details such as hue and texture, leaving appearance variation within a diagnostic class hard to control. CLNA adds a style encoder and dual cross-attention to a Stable Diffusion 2.1 backbone, compressing such non-prompt attributes into a continuous latent whose sampling range is set by a style parameter. Across normal tympanic membrane, otitis media with effusion and chronic otitis media, FID against the held-out internal test set fell from 52.91 for baseline Stable Diffusion to 10.11, and feature-space recall rose from 57.67% to 90.22%.

  3. arXiv

    A test set missing night images picks the wrong model: rewriting day photos into night restores the selection a fully covered set would make

    When a test set underrepresents a semantic condition such as night, model selection can be misled; a generative pipeline uses vision-language models to find the missing semantics and diffusion models to turn day images into night images, so the augmented test set selects the same model as a fully covered one.

  4. Scoliosis CT labels without hand annotation: bending healthy spines into pathological shapes lifts vertebra Dice from 0.765 to 0.842

    Vertebra segmentation in severe scoliosis has been limited by scarce annotated pathological CT, since public data contain almost no scoliotic cases. An anatomy-aware synthesis pipeline jointly deforms public healthy spine CT scans and their segmentation labels into scoliosis-like volumes, then trains nnU-Net CNN and PRIMUS models under matched compute. On 18 in-house adolescent scoliosis CTs, the best CNN setting raised mean Dice from 0.765 to 0.842 and vertebra success rate from 73.2% to 81.6%; on 55 surgeon-defined apical labels, mean Dice rose from 0.720 to 0.854.

  5. arXiv

    DAFL's distributed augmentation allocation lifts minority-class F1 to 0.183 and shortens convergence on CIFAR-10 federated learning

    The work first links data augmentation to federated learning convergence behavior, showing that reducing label proportion imbalance accelerates convergence, and then proposes DAFL: with clients' class counts known, the server assigns the minimum augmentation per client-class pair by minimizing augmentation and training time while constraining global class imbalance; on six imbalanced configurations of CIFAR-10 with eight classes and eight clients, DAFL achieves higher minority-class F1 with shorter training time on D2, D4, D5, and D6, reaching minority-class F1 0.183±0.055 and convergence time 188.119±86.344 s on D2, outperforming FedProx and Focal Loss.

  6. arXiv

    Extending mDPO to Audio: Qwen2-Audio Gains 14.0 Points on DCASE 2025 and 27.4 Points on AH Existence

    This work ports multimodal Direct Preference Optimization (mDPO) from vision-language models to the audio domain, building preference pairs that contrast intact audio with acoustically perturbed audio (reversal, random noise, time and frequency masking) and training Qwen2-Audio-7B-Instruct, raising DCASE 2025 audio QA accuracy from 56.0% to 70.0% and AH Existence accuracy from 55.6% to 83.0%.

  7. Retina

    Oracle-curated synthetic fundus images lift ConvNeXt diabetic retinopathy grading kappa from 0.6350 to 0.7695 and double proliferative DR recall

    The study pretrained StyleGAN3 and Medfusion on an auxiliary dataset, curated synthetic images through a domain-matched Oracle network using Latent Space Rejection Sampling and Class-Conditioned SDEdit Escalation, and evaluated downstream grading on the Indian DR Image Dataset across ConvNeXt, ResNet50, and VGG16 with five random seeds, finding that a real-data-only ConvNeXt baseline reached a quadratic weighted kappa of 0.6350 ± 0.0135, curated StyleGAN3 augmentation raised it to 0.7185 ± 0.0309, Medfusion augmentation reached 0.7695 ± 0.0254 (an absolute improvement of 0.1345), and Medfusion doubled proliferative DR recall from 0.2615 ± 0.1595 to 0.5385 ± 0.0942.

  8. Acta Scientiae

    Survey reports that AI combining behavioral, genetic, and imaging data with GAN-based augmentation may improve autism spectrum disorder screening, but limited data, class imbalance, and scarce external clinical validation remain

    This survey reviews AI, machine learning, deep learning, and generative adversarial network (GAN) approaches to autism spectrum disorder (ASD) screening, focusing on multimodal learning across behavioral, genetic, environmental, neuroimaging, physiological, and clinical data and on the role of GANs in synthetic-data generation and augmentation, concluding that multimodal AI may represent ASD-related characteristics more comprehensively than single-modality approaches while facing challenges of limited and heterogeneous datasets, class imbalance, multimodal integration, GAN training instability, synthetic-data quality, privacy and security, interpretability, generalizability, and limited external clinical validation.

  9. arXiv

    SAW conditions surgical video diffusion on four lightweight signals, cutting CD-FVD to 199.19 and lifting rare-action F1 from 20.93% to 43.14%

    The work proposes Surgical Action World (SAW), which reformulates video-to-video diffusion as trajectory-conditioned surgical action synthesis conditioned only on four lightweight signals—a language prompt, a reference first frame, a tissue affordance mask, and 2D tool-tip trajectories—fine-tunes LTX-Video on a custom-curated dataset of 12,044 laparoscopic clips with a depth consistency loss, reaches CD-FVD 199.19 (vs. 546.82 for SurgSora) and FVD 224.28 on held-out test data, and demonstrates that augmenting rare actions with generated videos improves action recognition on real test data (clipping F1 20.93% to 43.14%; cutting 0.00% to 8.33%) plus initial feasibility of rendering tool-tissue interaction videos from simulator-derived trajectories.

You’re all caught up