Skip to main content
Search

# Knowledge Graph Grounding

2 related articles

Subscribe to updates
  1. Patient-safety reasoning without the knowledge graph loses 0.047 F1, while retrieval's gain straddles zero

    Patient-safety reasoning requires linking clinical narratives, medications, laboratory findings and adverse events, and a language model alone can produce plausible but unsupported conclusions. The same MIMIC-III/IV cases ran under four conditions with one LLaMA 2 7B model and one prompt: model only, plus retrieval-augmented generation, plus a patient-safety knowledge graph and ontology, and both. The full framework reached F1 0.89 for concept extraction, 0.046 above baseline; removing the knowledge graph cost the most, with F1 0.047, AUROC 0.084 and AUPRC 0.110, while removing retrieval gave an F1 difference of 0.029 whose interval crossed zero.

  2. Medication recommendation stops at a drug list: RES-MR writes the diagnostic reasoning first, then prescribes inside each patient's own risk boundary

    RES-MR splits medication recommendation into two steps, first generating a checkable diagnostic reasoning chain and then adjusting the prescription to each patient's own risk boundary, reaching a 7.7% higher Jaccard than FLAME on MIMIC-III with lower DDI and RIS.