Sewer digital twins stop retraining per pipe: the FLOOD operator predicts across unseen pipes and networks, about 5,500-fold faster on one pipe
Sewer hydraulic digital twins have been limited by the cost of solving the Saint-Venant equations, while existing machine-learning surrogates need retraining for each new pipe or flow regime. FLOOD learns the solution operator of the Saint-Venant equations with a multi-branch neural operator, taking pipe geometry, hydraulic parameters and water levels at both manholes as inputs and returning depth and flow rate. On pipes excluded from training it reaches coefficients of determination of 1.000 for depth and 0.999 for flow rate, speeds up single-pipe online prediction by about 5,500-fold, and also serves roughness calibration and leakage localization.