    Copper fatigue simulations expose a blind spot in foundation potentials: NequIP's intrinsic stacking-fault energy is seven times lower than EAM's, and its cracks heal more often

    In cyclic-loading simulations of copper, the NequIP foundation interatomic potential agrees broadly with an experimentally vetted EAM potential on near-equilibrium properties, yet predicts an intrinsic stacking-fault energy about seven times lower than EAM, so crack tips emit partial dislocations more readily and flaws heal more often under fatigue. The study runs 72 fatigue simulations per potential on a Griffith crack geometry across three tensile axes, 50 to 500 K and 2 to 5 GPa pre-stress, separating equilibrium properties from emergent behavior that requires external work to trigger.