Skip to main content
Search

# Robotic Ultrasound

3 related articles

Subscribe to updates
  1. arXiv

    UltraWorld self-distills an interactive ultrasound world model from untracked clinical videos, cutting terminal distance and orientation error by 29% and 38% versus visual servoing across nine simulated closed-loop planning episodes

    UltraWorld presents a self-distillation recipe that first adapts clinical ultrasound videos into a generator conditioned on reference images and anatomical masks, then synthesizes action-video pairs by sampling masks along programmable trajectories through 3D anatomy, distilling the generator into a world model that predicts future observations from local observations and actions alone, and introduces the Acoustic Sampling Map representing probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths; experiments show improved prediction fidelity and action following, with mean terminal distance and orientation error reduced by 29% and 38% versus visual servoing across nine simulated closed-loop local planning episodes.

  2. arXiv

    An RL-fine-tuned small model lets a robot follow ultrasound guidelines to scan gallbladder, spine, and kidney autonomously

    The work proposes an autonomous robotic ultrasound framework driven by an LLM agent that retrieves guideline steps from scanning handbooks, reasons over current observations and scanning state, and dynamically invokes tools for trajectory planning, robot execution, contact adjustment, voice guidance, and trajectory refinement, with reinforcement-learning (PPO) fine-tuning to improve reasoning quality and the correctness of tool selection and parameterization; validated verbally on 10 unseen ultrasound scanning guidelines, fine-tuning raised step-wise accuracy from 0.6512 to 0.8973 and overall success rate from 0.5384 to 0.

  3. arXiv

    Robotic ultrasound drives real-time CBCT slice updating: USCorUNet cuts forward-backward residual by about 53% and updates a slice in 11.25 ms

    The work proposes a deformation-aware CBCT updating framework that uses robotic ultrasound as a dynamic proxy to infer tissue motion: after hand-eye calibration initialization and LC2-based rigid refinement, a lightweight network, USCorUNet, estimates dense bidirectional deformation fields from adjacent ultrasound frames, which are spatially regularized and transferred to the CBCT reference slice, enabling real-time end-to-end CBCT slice updating without additional radiation exposure, validated on phantom and in vivo data for both deformation estimation and ultrasound-guided CBCT updating.

You’re all caught up