    Brain MRI no longer needs all three stacks: MS-HVED rebuilds from whatever orientations exist, and experts preferred it in 187 of 210 Nigerian pairs

    MS-HVED encodes each available axial, coronal or sagittal low-resolution brain MRI stack into a multi-scale Gaussian posterior and fuses them with a field-of-view-aware product, so one trained model accepts any non-empty subset of orientations without retraining. In a blinded reader study on 30 routine brain MRI examinations from a Nigerian cohort, seven expert neuroradiologists preferred MS-HVED over the supervised SegResNet baseline for overall image quality in 187 of 210 paired assessments, and the preference persisted when an axial or coronal input was deliberately omitted.