Skip to main content
Search

Artificial Intelligence in Medicine (Canada)

4 related articles

Subscribe to updates
  1. Retrained on Nigerian scans, a brain-age model reaches 9.82 years of error, then 8.78 on a second cohort

    Brain-age models trained mostly on Global North data lose accuracy when applied to Nigerian adults. A population-specific Gaussian process regression model trained on clinical T1-weighted MRI from 309 Nigerian adults reached a mean absolute error of 9.82 years on a 47-participant held-out test set without age-bias correction; on the 44-participant head-to-head set it reached 10.24 years, against 10.52 years for PyBrainAge, 12.33 for SynthBA, 17.51 for ENIGMA-Brain Age and 7.87 for SPARROW. After correction it reached 6.39 years internally but 8.78 years on a separate Nigerian cohort, where every model's R2 was negative.

  2. arXiv

    CredLeak-Bench: All seven tested LLM agents leaked credentials to phishing, with recovery topping out at 24.2%

    The authors introduce CredLeak-Bench, a sandboxed benchmark that measures leakage through actual submissions of synthetic credentials across directed authentication, autonomous inbox monitoring, and recovery settings with paired legitimate controls; evaluating seven models, they find every model leaks in both primary settings, phishing can induce disclosure without any authentication request, most leakage-reducing mitigations also impair legitimate task completion, and recovery ranges only from 0% to 24.2%.

  3. arXiv

    Sparse autoencoders trained on 909,873 CT/MRI slices decompose medical foundation-model embeddings into language-describable concepts, recovering 87.8% of downstream performance with 10 features

    Trained on 909,873 2D CT and MRI slices from the TotalSegmentator dataset, this study fits Matryoshka sparse autoencoders with BatchTopK sparsification on frozen embeddings from BiomedParse (biomedical) and DINOv3 (general-purpose) foundation models alongside a random-weight baseline, finding that sparse features reconstruct original embeddings with R2 up to 0.941, recover 87.8% of downstream performance with only 10 features (99.4% dimensionality reduction), preserve 97.7% of dense retrieval quality with five-feature fingerprints, correspond to monosemantic concepts expressible in language as verified by an independent LLM judge, and enable zero-shot language-driven image retrieval on a single clinical text query.

  4. arXiv

    AIDEN solves real-space charge density with an equivariant network, reaching state-of-the-art accuracy on periodic crystal benchmarks and zero-shot transfer across structures

    The authors propose AIDEN, an Atomic-Interaction Density Equivariant Network for real-space charge density, which separates the element-dependent one-center density from environment-induced density redistribution, represents the latter through complementary atom- and edge-centered tensor correlations, and reconstructs density at arbitrary spatial coordinates with a continuous low-rank Gaussian decoder; it achieves state-of-the-art accuracy on periodic crystal benchmarks, remains competitive for molecular systems, shows zero-shot transferability across several structurally distinct out-of-distribution case studies, and offers substantially faster inference than both baseline models and full SCF calculations.

You’re all caught up