Skip to main content
Search

Sun Yat-sen University Cancer Center

3 related articles

Subscribe to updates
  1. arXiv

    SegDINO reshapes DINOv3 with lightweight scale modeling, reaching top segmentation accuracy across four datasets at 27.68M parameters and 51 FPS

    The work presents SegDINO, which uses a frozen DINOv3-S encoder to collect intermediate features from layers 3, 6, 9, and 12, reorganizes same-resolution tokens into a pseudo multi-scale pyramid via Token Pyramid Adaptation (TPA), and applies Scale-Aware Decoding (SAD) for intra-scale refinement and top-down inter-scale propagation, alongside a new PanCT dataset of 284 pancreatic cancer patient CT scans; on PanCT and the public TN3K, Kvasir-SEG, and ISIC benchmarks, SegDINO outperforms U-Net, SegNet, R2U-Net, Attention U-Net, TransUNet, U-NeXt, and U-KAN in both DSC and HD95, with 27.68M total parameters and 51 FPS inference.

  2. Clinical Implementation and Evaluation of an Artificial Intelligence-Driven One-Click Automatic Planning System for Functional Lung Avoidance Radiotherapy

    This study implemented AP-FLART, which integrates dosimetric score-based beam angle selection, multi-modality-guided dose prediction, and function-guided dose mimicking, within RayStation and evaluated it on a test dataset of 33 lung cancer patients who underwent SPECT ventilation or perfusion imaging and lung radiotherapy, finding that automatic FLART plans significantly reduced high-function lung mean dose by 15.1% versus manual conventional radiotherapy plans, lowered the probability of grade >=2 radiation pneumonitis by 6.25 percentage points (27%) among FLART-benefiting patients, achieved clinical benefits similar to manual FLART plans, were clinically acceptable without modification in 87.9% of cases, and cut planning time from 2-3 hours to approximately 8 minutes.

  3. GPT-assisted radiomic modeling for predicting pathological complete response to neoadjuvant chemoimmunotherapy in head and neck squamous cell carcinoma

    In a training cohort (n = 186), a validation cohort (n = 116), and a prospective multicenter validation cohort (n = 269), this study extracted radiomic and supervised deep learning features from pretreatment T2-weighted MRI and compared manually developed with GPT-assisted modeling workflows, finding that fused features achieved the highest AUC for both manually developed and GPT-assisted logistic regression models (0.759 versus 0.763 ± 0.003 in the training cohort, 0.714 versus 0.741 ± 0.008 in the validation cohort, and 0.700 versus 0.706 ± 0.

You’re all caught up