Skip to main content
Search

Zhongshan Hospital

5 related articles

Subscribe to updates
  1. bioRxiv

    A phage DNA model learns to denoise both ways: CPDD corrects 42.4% of visible wrong bases in one pass

    Autoregressive DNA language models generate left to right, yet genome repair and editing usually condition on both flanks. The CreatiPhage team converted a 144.5M-parameter phage autoregressive model into CPDD, a 147.5M-parameter bidirectional discrete diffusion model; on 522 screened phage coding sequences it restores randomly masked bases more accurately than the comparable diffusion model PhaGen, and in a mixed-corruption test a single forward pass returns 42.4% of visible incorrect bases to the correct base.

  2. arXiv

    Alibaba DAMO's HoloCT fuses CT reading and 3D segmentation in one model, surpassing all four radiologists in sensitivity and overall accuracy in a multicentre reader study

    Alibaba DAMO Academy's HoloCT is a 3D CT foundation model that puts scan interpretation and voxel-level segmentation inside one vision–language model, so a textual finding can come with a checkable 3D mask. Previously, segmentation networks delineated without interpreting, and CT vision–language models wrote text without voxel-level localization. On 11,455 clinical CT scans from five hospitals, HoloCT-8B raised mean Dice over VoxTell from 0.107 to 0.488 on laryngeal lesions and from 0.543 to 0.715 on lung cancer, and in retrospective reader studies of thyroid tumours and colon lesions it exceeded all four participating radiologists in sensitivity and overall accuracy.

  3. arXiv

    A coronary agent now shows its evidence before its answer: the gate passes 76.7%, and rejects half of reference lesions

    Panvascular intervention research is starting to write traceability into an agent's output contract: ScienceBuddy-PV fixes a shared convolutional model on the public ARCADE coronary angiography benchmark and evaluates only an evidence gate and action audit, where the gate accepts 76.7% of stenosis-frame candidates against 100% for a score-only comparator. On the locked test set, stenosis Dice is 0.231 and AUROC is 0.957 at a pixel prevalence of 0.00975, while reference lesion candidates are accepted 44.3% and rejected 55.7% of the time. The result is an image-level technical validation; recursive harness optimization and model learning remain protocols rather than executed experiments.

  4. medRxiv

    StrokeAgent matched expert final decisions in 86% of 100 acute stroke cases, exceeding tool-free LLMs and neurologists

    The study presents StrokeAgent, a multimodal agentic decision-support framework built around temporal alignment and continuous information synthesis that processes clinical records, laboratory results, raw electrocardiographic (ECG) waveforms and source multimodal CT images to support emergency triage, the initial thrombolysis decision and final reperfusion planning, and in a curated set of 100 patients with multimodal clinical and imaging data enriched for clinically complex reperfusion scenarios it achieved 86% concordance with expert-adjudicated final decisions, exceeding the mean of three tool-free large language models by 13 percentage points and the mean of six resident and attending neurologists by 17 percentage points, with 76% complete pathway concordance, completing the full deci

  5. bioRxiv

    EvSpark: Lossless Speculative Decoding for Hybrid DNA Foundation Models

    EvSpark is a speculative decoding system for hybrid convolutional-recurrent-attention DNA foundation models such as Evo2: it verifies draft blocks in parallel and restores all three classes of inference state by selecting retained intermediate states without replay, reaching 2.96x on 43 real-sequence prompts and 3.27x including five synthetic controls on an Evo2 7B 48-prompt benchmark with three training seeds, retaining 1.84x-2.43x at 262k context, and yielding 2.18x-2.46x on real sequences and 2.51x-2.78x on the full suite for 20B and 40B targets.

You’re all caught up